PLAYGROUND  EQUIPMENT

ABOUT US

MATERIALS

SAFETY & ACCESSIBILITY            

WARRANTY

SURFACING & INSTALLATION

CONTACT US

JOIN OUR TEAM!

NEWS & EVENTS

HOME

SEND ME
a Playground
Equipment
Catalog!

 

 

RSP TEST RESULTS & CONCLUSIONS - FOR PLAY MART, INC.
(RECYCLED STRUCTURAL PLASTICS)
 MECHANICAL ENGINEERING TESTING LAB AT LEHIGH UNIVERSITY, BETHLEHEM,PA. 
MAY 1998 C.J. COGHLAN 
RSP 3.1 TEST: PLASTIC LUMBER BENDING TESTS - 1998 RSP PMI IN-HOUSE TEST: MINI DECK LOADING TESTS - 2001 

3.1 TEST: PLASTIC LUMBER BENDING TESTS - (STRUCTURAL RESISTANCE TO BENDING)

MATERIAL & SIZE

MAXIMUM LOAD MAXIMUM STRESS BENDING MODULUS

WOOD 2 X 4

2834.75 LBS. 6106.92 psi. 10,689,413 psi

RSP 2 X 4

2128.23 LBS. 3691.15 psi 1,136,508 psi

WOOD 1 X 6

680.84 LBS. 6106.92 psi 6,455,095 psi

RSP 1 X 6

1178.06 LBS. 3583.11 psi 1,342,644.3 psi
WOOD 2 X 6 1980.26 LBS. 4440.57 psi 7,215,713 psi
RSP 2 X 6 2672.57 LBS. 3090.17 psi 1,084,108 psi
RSP is stronger than wood in some tests. RSP is more flexible than wood.

CONCLUSION 1: RSP IS ULTIMATELY STRONGER THAN WOOD IN MAXIMUM LOADING IN TWO TESTS, BUT REMAINS MORE FLEXIBLE WITH LESS RESISTANCE TO BENDING. (SEE TESTS WITH STEEL INSERTS FOR HORIZONTAL BEAM APPLICATIONS.)

3.1.5 Conclusions: "From these results, it is evident that RSP beams are more flexible and fail at lower stresses than their wooden counterparts."

PMI IN-HOUSE TEST 2001: PLASTIC LUMBER BENDING TESTS - (STRUCTURAL RESISTANCE TO BENDING) CURRENT MINI DECK WITH NO STEEL INSERTS - LOADING TEST.

PMI MINI DECK 2001
 DECK MATERIAL SIZE MAXIMUM LOAD MAXIMUM LOAD DURATION & TEMPERATURE MAXIMUM DEFLECTION
RSP 5/4" X 6" 
FRAMES & TOPS
1000 LBS. LIVE & DEAD LOADS 100 HOURS PASSED WITH 1/240 DEFLECTION
DECK SIZE 
23" X 30" X 7"
200 PSF. 60 TO 100 DEG. F. FLUCTUATION NO FAILURE
DECK SUPPORTS SIZE (4) - 3.5" X 3.5" X 10"
HARDWARE SIZES  DECK TOP HARDWARE - (48) #10 X 2.5" SS SQUARE DRIVE DECK SCREWS. DECK FRAME HARDWARE - (24) #10 X 3" SS SQUARE DRIVE DECK SCREWS. POST & FRAME HARDWARE - (8) 3/8" X 4" SS HEX DRIVE LAG BOLTS.

CONCLUSION 2: RSP IS STRONG IN MAXIMUM LOADING IN MINI DECK TESTS, DUE TO CLOSER JOIST SPACING IN THE DECK DESIGN, AND PASSED A 200 PSF LOADING TEST, DOUBLE THE CODE REQUIREMENT FOR MANY COMMERCIAL APPLICATIONS. 

RSP STRUCTURE IS FLEXIBLE & SAFER, WITH APPROPRIATE DESIGN FOR RECYCLED MATERIALS. 

Back to Materials Page

  Play Mart's GSA Contract & References

home    playground equipment    about us    materials    safety & accessibility   warranty 

surfacing & installation   contact us   join our team  resources

Comments or questions about our site?
Please contact our Webmaster.

 
© Copyright 2003 Play Mart, Inc. All Rights Reserved